Oil pumps in CHPs

In order to convert passenger-vehicle engines into CHP motors, they must be adapted to stationary operation. Important above all is the permanent supply of sufficient fresh oil to the unit. Scherzinger can supply you with gear pumps for the pressure buildup prior to start-up, the oil change, and the bypass filtration in your CHP.

Operating ranges

Flow rate 0.5 l/min to 40 l/min
Differential pressure 0.3 bar to 10 bar
Viscosity range 3 mPas to 10,000 mPas
Suction head Up to 8 m
Temperature range -30°C to 140°C
Inlet pressure Up to 10 bar

Examples of fluids

  • Engine oil
  • Gas engine oil
  • Diesel engine oil